NATA-Accredited Temperature Calibration
NATA-Accredited Temperature Calibration
Hinco Instruments operates a NATA-accredited temperature calibration laboratory in Canning Vale, Perth, accredited to ISO/IEC 17025 — the international standard for the competence of testing and calibration laboratories. We have calibrated temperature instruments for Western Australian industry for 70 years and serve customers across Australia.
Our accreditation number is 21447, and it can be verified directly on the NATA register. Accreditation means our temperature measurements have been independently assessed for technical competence, traceability and measurement uncertainty. Through international mutual recognition arrangements, a NATA-endorsed certificate is accepted overseas as well as nationally.
Need a temperature calibration?
Tell us the instrument type, make and model, how many units, and whether you need a NATA-endorsed certificate.
Check us on the register
Our accreditation and its scope are published by NATA. Verify accreditation 21447 before you send anything.

What we calibrate
On our accredited scope
Calibrated under our NATA accreditation, issued on a NATA-endorsed certificate.
- Digital thermometers with probe, −25 to 150 °C
- High-temperature thermometers, 150 to 1000 °C
- RTD probes
- Thermocouple probes
- Temperature loggers
- Data loggers with temperature sensors
- Temperature controllers
- Temperature switches
- Dry block calibrators, −25 to 150 °C and 150 to 1000 °C
- Process meter RTD and thermocouple simulation
Also calibrated, traceable
Not every temperature instrument sits on our accredited scope, and we would rather say so than let you assume. These are calibrated in the same laboratory with traceable results, on a Hinco certificate rather than a NATA-endorsed one.
- Infrared thermometers
- Thermal imaging cameras
- Fluid (mercury-in-glass) thermometers
- Chart recorders
- Capillary and thermistor sensors
Good to know
Single and multi-point
Digital instruments can be calibrated at one or two temperatures depending on how they are used. Loggers and probes are typically done at three points across the working range. Tell us where the instrument is used and we will advise.
Calibration intervals
Twelve months is the usual interval. Shorten it where the instrument is critical to product safety, used in harsh conditions, or has been subject to mechanical shock. Tell us your due dates and we will remind you.
Our scope of accreditation
Published on the NATA register. If you need to confirm a specific measurement is covered before sending an instrument, the scope is the document to check — and we are happy to walk through it with you.
Industries we support
Food and beverage, medical and laboratory, mining and engineering, oil and gas, manufacturing and production, logistics and cold chain, HVAC and refrigeration, waste water, and utilities.
Other calibration services
Temperature is one of several disciplines we cover. See also pressure gauge calibration, environmental monitoring calibration, water quality sensor calibration, and on-site calibration services, or browse our full range of calibration and repair services.
Request a temperature calibration quote
Tell us the instrument type, make and model, how many units, and whether you need a NATA-endorsed certificate. We will come back with a quote and turnaround.