nata ariba qc

Gas Detector Calibration

Hinco Instruments calibrates portable and fixed gas detectors for mining, oil and gas, water utilities, construction and manufacturing. Personal single-gas and multi-gas monitors are calibrated in our Canning Vale workshop, and fixed gas detection systems can be calibrated on site. We serve customers across Australia from our Perth, WA base.

Detectors are calibrated with certified calibration gas, and we calibrate the brands we sell, such as Crowcon, as well as MSA, Dräger, Honeywell and many others.

Need gas detectors calibrated?

Tell us the make, model, the gases each unit measures and how many units. We will come back with a quote and turnaround.

Looking to buy?

We supply portable and fixed gas detectors from Macurco (a DwyerOmega brand), Crowcon and CTI, plus calibration gas.

Hinco Instruments technician servicing gas detection equipment at an industrial gas site in Western Australia
Gas detection equipment serviced on site by Hinco Instruments.

What we calibrate

Portable monitors come into our workshop. Fixed systems are calibrated where they are installed.


Single-gas detectors

Personal monitors for a single hazard such as H2S, CO or O2, worn by operators and contractors.


Multi-gas detectors

Four and five-gas personal and confined-space monitors, pumped or diffusion, such as the Crowcon Gas-Pro.


Fixed gas detectors

Fixed-point flammable, toxic and oxygen detectors in plant rooms, pump stations and process areas, calibrated on site.


Gas leak detection systems

Refrigerant, ammonia and other leak detection systems, checked against certified gas to confirm alarm set points.

Bump test or calibration?

They are different checks, and you need both. A bump test briefly exposes the detector to a known gas to prove the sensors respond and the alarms go off. It is a quick functional check, and most manufacturers recommend one before each day’s use.

A calibration adjusts each sensor against a certified gas concentration so the reading on the display is correct, not just responsive. Most manufacturers specify a full calibration at least every six months, and more often where detectors work in harsh conditions or fail a bump test. Always follow your detector’s manual and your site procedure.

If you run your own bump tests, we supply calibration gas and bump test and calibration stations.

Traceable calibration, and what that means

Gas detector calibration at Hinco is traceable calibration: detectors are set against certified calibration gas, and the gas certificates are recorded with your calibration results.

Good to know

On site or in the workshop

Send portable detectors to our Canning Vale workshop, or ask about a site visit for fixed systems and larger fleets.

Tell us your due dates and we will remind you when detectors fall due, so calibration is scheduled rather than discovered during an audit.

Certificates and repairs

Every calibration is issued with a certificate recording the as-found and as-left readings and the calibration gas used.

Where a detector fails calibration, for example because a sensor has reached the end of its life, we will tell you what is wrong and what a repair would involve before doing the work.

Need it back fast? Priority calibration is available for an additional fee. Call us on 08 9455 6777 or contact us to book.

Other calibration services

See also on-site calibration services, environmental monitoring calibration, NATA-accredited temperature calibration, or our full range of calibration and repair services. You can also browse the gas detectors we calibrate.

Request a gas detector calibration quote

Tell us the make, model, the gases measured and how many detectors you need calibrated.

Speak With a Calibration Technician