nata ariba qc

Wika DPT-20 Differential Pressure Transmitter

The Wika DPT-20 Differential Pressure Transmitter, has high measurement accuracy, 4 … 20 mA, 4 … 20 mA HART®, FOUNDATION™ Fieldbus or PROFIBUS® PA output signals, and intrinsic safety or flameproof enclosure ignition protection type.

The WIKA DPT-20 is a differential pressure transmitter for industrial process applications, offering 4–20 mA, HART®, FOUNDATION™ Fieldbus, and PROFIBUS® PA output options. Developed to SIL (Safety Integrity Level) requirements per IEC 61508, the DPT-20 is suitable for plants with elevated safety requirements and is available with intrinsic safety or flameproof enclosure ignition protection.

Measuring ranges extend from -10/+10 mbar to -16/+16 bar, making the DPT-20 versatile across flow measurement, level monitoring, and filter and pump condition monitoring. When fitted with diaphragm seals, it is also suitable for harsh process media.

Hinco Instruments supplies WIKA differential pressure transmitters across Perth and Western Australia for the mining, oil and gas, water, and process industries.

Key Features of the WIKA DPT-20 Differential Pressure Transmitter

  • Differential pressure measurement
  • Output: 4–20 mA, HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA
  • SIL-capable per IEC 61508
  • Intrinsic safety and flameproof versions available
  • Measuring ranges from -10/+10 mbar to -16/+16 bar
  • Compatible with diaphragm seals for harsh media

Browse all pressure instruments at Hinco or contact us for application advice.

Download PDF

Specifications

Measurement Type Differential pressure
Output Signals 4–20 mA, 4–20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA
Measuring Ranges -10/+10 mbar to -16/+16 bar
SIL Capability Yes — per IEC 61508
Ignition Protection Intrinsic safety or flameproof enclosure (optional)
Diaphragm Seal Compatible
Approvals ATEX, IECEx (hazardous area versions)

Applications

The WIKA DPT-20 is used for differential pressure measurement across a wide range of industrial processes:

  • Flow measurement using differential pressure (orifice plates, Venturi tubes)
  • Level measurement in open and closed tanks
  • Filter condition monitoring (pressure drop across filter elements)
  • Pump monitoring and condition assessment
  • Process safety systems requiring SIL-rated instruments
  • Oil and gas and chemical processing hazardous areas
  • Water and wastewater treatment

Documents

0
    0
    Your Cart
    Your cart is emptyReturn to Shop