Specifications
| Part Number | 103DS2VH2A |
|---|---|
| Target Gas | Hydrogen (H₂) |
| Concentration | 2% by volume (≈ 50% LEL) |
| Balance Gas | Air |
| Cylinder | 103 L disposable, non-refillable steel |
| Valve Connection | C10 (5/8"-18 UNF) |
| Certification | Traceable to ISO 17034 / ISO 17025 |
Certified 2% volume hydrogen in air calibration gas (approx. 50% LEL) in a 103 L disposable steel cylinder for hydrogen and combustible-gas detectors.
The CAC 103DS2VH2A is a certified 2% by volume hydrogen in air calibration gas supplied in a 103 litre disposable steel cylinder. At roughly half of hydrogen’s lower explosive limit, it is the natural span point for hydrogen-specific and combustible-gas detectors.
Hydrogen detection matters in battery rooms, BESS sites, electrolysers, chemical processing and anywhere lead-acid batteries are charged. Calibrating with hydrogen itself, rather than relying on a methane cross-reference, gives the most accurate response from sensors watching for a hydrogen leak. Pair it with a CAC FF-100 fixed-flow regulator for accurate delivery to your gas detectors.
Browse the full CAC calibration gas range, see our calibration services or contact us for pricing and stock. Hinco Instruments supplies, repairs and calibrates gas detection equipment in Western Australia.
| Part Number | 103DS2VH2A |
|---|---|
| Target Gas | Hydrogen (H₂) |
| Concentration | 2% by volume (≈ 50% LEL) |
| Balance Gas | Air |
| Cylinder | 103 L disposable, non-refillable steel |
| Valve Connection | C10 (5/8"-18 UNF) |
| Certification | Traceable to ISO 17034 / ISO 17025 |