nata ariba qc

CAC 103DS1VCH4A Methane in Air Test Gas

Certified 1.0% volume methane-in-air calibration gas (approx. 20% LEL) for low-span verification and bump testing of combustible-gas detectors.

The CAC 103DS1VCH4A supplies a methane-in-air mixture at the lower end of the combustible range, giving technicians a dependable low-span point when calibrating flammable-gas detectors. At roughly one-fifth of the lower explosive limit, it is ideal for confirming that a monitor responds early – well before an atmosphere becomes dangerous.

Built for catalytic and infrared LEL sensors

Combustible-gas sensors gradually lose sensitivity as catalytic beads age or optics foul. Calibrating with the 103DS1VCH4A methane test gas restores confidence that the %LEL reading on the display reflects the real hazard rather than a drifting sensor.

A repeatable low-span reference

Methane in air is the accepted benchmark for LEL calibration, and a stable certified blend removes the guesswork from routine gas-detector servicing and pre-entry checks.

For controlled delivery, use a CAC FF-100 regulator. Talk to Hinco Instruments in Perth for pricing, availability and matching span gases.

Call 08 9455 6777
Download PDF

Specifications

Target Gas Methane (CH₄)
Concentration 1.0% by volume (≈ 20% LEL)
Balance Gas Synthetic Air
Cylinder Type Disposable, non-refillable aluminium
Valve Connection C10 (5/8"-18 UNF)
Shelf Life 36 months from date of manufacture
Certification Traceable to ISO 17034 / ISO 17025
Physical State Compressed gas – colourless, odourless
UN Number 1956 (Compressed gas, N.O.S.)

Applications

The CAC 103DS1VCH4A supplies a 1.0% v/v methane-in-air mixture (approximately 20% LEL) for low-span calibration of combustible-gas detectors:

  • Calibration of catalytic bead (pellistor) LEL sensors
  • Low-span (20% LEL) verification of portable multi-gas detectors
  • Methane (firedamp) detector calibration for underground mining
  • Landfill and biogas monitoring equipment calibration
  • Bump testing fixed combustible-gas detection systems
  • Verification of %LEL channels on confined-space monitors
  • Laboratory reference gas for methane sensor testing

Documents

Hinco Instruments is your authorised CAC specialty gas distributor in Perth, WA. Contact us for pricing, availability, cylinder options, and technical support.

Request a quote

Enquiring about: CAC 103DS1VCH4A Methane in Air Test Gas

Tell us what you need and our team will come back to you with pricing and availability, usually within one business day.

Name
Call us
0
0
Your Cart
Your cart is emptyReturn to Shop